![]() If the application number is earlier than 1.05b, you will need to update the firmware. If the application number is 1.05b or later, the DSC260 is ready for remote control and you can skip ahead to Making control connections on page 2. The number beginning with A is the application version the field-updatable software. When you first power the unit up, you should see something like this: JBL DSC-260 B0.12 A1.01 The number beginning with B is the boot version. The DSC260, the firmware version, actually consisting of two separate numbers, appears briefly on the front panel display during boot-up. The firmware version shipped with most DCS260s currently in the field does not support external control of this device and will need to be updated. Preparing a DSC260 for Remote Control The first step in preparing a DSC260 system controller for remote control using SIA-Smaart Pro is to check the version number of the firmware (device-specific software stored in nonvolatile memory) currently running on the unit you want to control. More general information about controlling external devices from Smaart Pro can be found in the SIA-Smaart Pro user s manual or the Real-Time Module help file. This document discusses details of the Real-Time module s external device control interface specific to the DSC260. An EAW Company The SIA-Smaart Pro Real-Time module can control crossover and delay functions on the DSC260 as well as output EQ, limiter, gain and phase compensation. ![]() ![]() 1 Controlling the JBL Professional DSC260 System Controller Using SIA-Smaart Pro SIA Software Company, Inc.